How to read this report
Test report

2026SP06971R01

Disinfection Efficacy for Domestic Drinking Water

Guangdong Detection Center of Microbiology · Gmicro Testing (广微测) · issued 2026-07-29

Report details

Report number2026SP06971R01
Test itemEvaluation of disinfection efficacy for domestic drinking water
ApplicantGuangdong Orange Filtration Technology Co., Ltd.
SamplePES ultrafiltration membrane filter cartridge
Test typeCommissioned testing (委托检测)
Sample received2026-07-20
Completed / issued2026-07-29
Test standardTechnical Standard for Disinfection (Ministry of Health, 2002 edition), Part 2, clause 2.1.4.1
Challenge organismEscherichia coli 8099
MethodChallenge water was prepared from pure water dosed with the organism; the filtrate was sampled and plated. Three independent runs, each with its own control.

Results

RunTest sample (CFU/100 mL)Control (CFU/100 mL)Removal
1< 13.3 × 10⁶> 99.9999%
2< 12.5 × 10⁶> 99.9999%
3< 12.9 × 10⁶> 99.9999%

Reading the numbers

Every run came in below 1 CFU per 100 mL, the limit of quantification, so the removal rate is a floor rather than a measured point: read it as "at least 99.9999% under these conditions".

The laboratory states that the results refer only to the sample tested, and the challenge water was pure water dosed with the organism rather than a real feed.

Full document

All four pages, reproduced in full. The issuing laboratory permits complete reproduction but not partial reproduction without written consent, which is why nothing here is cropped to the results page.

2026SP06971R01 Page 1 of 4 — cover: report number, sample name, applicant, laboratory address.
Page 1 of 4 — cover: report number, sample name, applicant, laboratory address.
2026SP06971R01 Page 2 of 4 — sample details, dates, test item, standard and method, signatures.
Page 2 of 4 — sample details, dates, test item, standard and method, signatures.
2026SP06971R01 Page 3 of 4 — results: three runs, control counts and removal rates, with the sample photograph.
Page 3 of 4 — results: three runs, control counts and removal rates, with the sample photograph.
2026SP06971R01 Page 4 of 4 — notice items, including that results refer only to the sample tested.
Page 4 of 4 — notice items, including that results refer only to the sample tested.

Ordering against a report

Send us the specification you need covered. We reply with the document that names that model, or we tell you plainly that we do not hold one - either answer is more useful than a percentage on a web page.